      Drug stability test chamber Constant temperature and humidity chamber Light incubator Artificial climate chamber Biochemical incubator
      DMT 250/460/78...
      DNK 250/460/76...
               
      high and low temperature and Humidity test chamber High and low temperature test chamber insect Incubators
         
  • Service & Support
  • News
    • Enterprise news
    • Recruitment
  • Contact us
 
  • 首页 >
  • Constant temperature and humidity chamber >
  • DNK 250/460/760

DNK 250/460/760

  • 产品介绍


Application scope

Pharmaceutical industry, food industry, cosmetic industry, microculture, biotechnology &environmental simulation, etc



       AIKANE constant temperature &humidity chamber can provide constant climatic conditions for stability test and the long-term stable climatic conditions shall comply with various standards and all requirements of ICH (International Council for Harmonization) guideline Q1A (R2) for new crude drug and preparation stability test.



联系方式

在线联系

电话

021-59965626 Hotline 热线

了解更多

-The 7’’true color touch panel, smart operating system and high-performance processor contribute to easy and simple operation.

-Fuzzy PID control and programmed multi-section parameter setting.

-Precise timing function with week, day and hour modes.

-With the quick upgrade system, system program can be directly upgraded with USB.

-The system has automatic storage function and can store data of 3 years.

-Real-time check of temperature and humidity data or curve (for the last 8 to 10 hours).

-With event record function, 16,000 data can be recorded (including ON, OFF, menu parameter setting, fault alarm, etc.) and directly exported with USB.

-Imported Danfoss (SECOP) compressor and German EBM condenser fan.

-German HERAEUS temperature sensor and Austrian E+E capacitive transducer as the humidity sensor.

-Data monitoring standard access port (Ø50 mm) on the right, with silica gel plug.

-With CFC/HFC-free polyurethane foam as insulation material of the chamber, excellent thermal insulation and anti-condensation performance is realized.

-Samples can be observed through the inner glass door, thus avoiding affecting temperature and humidity due to door opening.-Flexible stainless steel -shelf system is easy to take out for cleaning and shelves have no sharp edges.

-Stainless steel liner (1.4301 / ASTM 304) and round corner design facilitate cleaning.

-Screensaver and coded lock prevent accidental operation.

-USB and RS485 interfaces.

-Chinese and English menu switch.

-When the temperature and humidity are set in the frostless range, the compressor works and the evaporator has no frost.

-When humidity is not needed, it can be set to zero and the equipment operates in the temperature mode; the control system can still ensure humidity inside the chamber.

-Energy saving: the energy saving effect is between 10% and 60% as the temperature and humidity settings change; water saving: the results change according to the temperature and humidity settings; for instance, a bottle of water can ensure operation of 30 to 60 days at the temperature of 25 °C and humidity of 60%. They jointly shorten working time of heating and humidification pipes, thereby extending their service life.


Technical parameter

Product model

DNK 250

DNK 460

DNK  760

Control mode/program

PID fuzzy logic control, common/program fuzzy operation

Temperature control range

 -10 °C~80 °C (-10 °C~90 °C/-40 °C~90 °C can be customized)

Humidity control range

 15~95%RH/ ±1.5%RH

Temperature fluctuation

±0.1 °C

Temperature uniformity at 25 °C

±0.5

±0.5 °C

±0.8℃

Humidity fluctuation

±1.5RH

Overall size (mm) W*H*D

750*1,578*837

975*1,848*887

1,480*1,848*987

Liner size (mm) W*H*D

580*980*440

795*1,180*490

1,300*1,180*500

Net weight

Approx. 196KG

Approx. 270KG

Approx.340KG

Effective volume

250L

460L

764L

Total power of heating and humidification

2200W

2500W

3600W

Refrigerating power • refrigerant

250W.R134A

550W.R404A

700W.R404A

Temperature and humidity sensors

German HERAEUS temperature sensor and imported E+E humidity sensor

Refrigerating method

Smart adjustment of compressor refrigerating capacity between 10% and 100%; large-scale frostless operation of refrigeration evaporation &significant reduction of energy and water consumption.

Working temperature

5 °C-35 °C; recommended working temperature is 10 °C-30 °C, in order to obtain optimal performance.

Supply voltage

AC-220 V  50/60 HZ

Safety device

Auto start, auto stop, power ON recovery, timing run, compressor over-voltage protection, over-temperature alarm, electric leakage protection, water shortage protection, door open protection, sensor anomaly alarm

(Standard) tray

3 layers (addable)

4 layers (addable)

4 layers (addable)

* Performance parameter testing under idle conditions: 25 °C ambient temperature

* Product appearance parameters may be changed without notice and product appearance may show deviations due to photography, printing and other reasons.

Tip: Please carefully read the instruction manual before use.


上一个产品:DHK 250/460/760    下一个产品:没有了  

产品

  • Drug stability test chamber
  • Constant temperature and humidity chamber
  • Light incubator
  • Artificial climate chamber
  • Biochemical incubator
  • high and low temperature and Humidity test chamber
  • High and low temperature test chamber
  • insect Incubators

About us

  • Company profile
  • Our mission
  • Management team

News

  • Enterprise news
  • Recruitment

Follow us

Mobile phone scan two dimensional code to pay attention to us

  • Leica Biosystems Logo

Copyright@2018 AIKANE 
沪ICP备18015075